Shaft swings may occur depending on the maximum pump heads ( the bottom one ) fluorine resin bearing radial clearance . According to the manufacturer 's standard , 9LDTN type condensate pump bearings allow maximum use of fluorine resin gap 0.4 mm, taking into account the fluorine resin bearing wear will not damage after mechanical seal , based on past experience overhaul , whichever heads fluorine resin bearing radial clearance to 2 mm. Principles calculations based on similar triangles , the mechanical seal shaft runout limit value of 0.24 mm, and then consider rolling under its own motor radial clearance is set to 0.1mm ( for 6226 bearing is damaged in terms of the gap ) , then mechanical shaft seals can get maximum runout of 0.34 mm. The selected mechanical seal allows runout of 0.5 ~ 0.7 mm, it will not damage the shaft for mechanical seal conical swing .
Transformation is due to the choice of cartridge single mechanical seal , installation is relatively simple and does not require any transformation of the pump , mechanical seal less work . However, in the transformation process involves the following considerations :
a) Check the condensate pump original packing sleeve outer periphery of ovality , elliptical too large to be replaced. Because mechanical seal sleeve must set this sleeve , with the Department by its O-ring indicative seal, sleeve oval spend much effect on the O-ring and sleeve contacts , causing leaks here .
b) packing sleeve and the shaft seal must be reliable without leakage, if packing between the sleeve and the shaft seal leakage , condensation will also affect water quality and vacuum unit .
c) the original packing chamber condensate pump outer face flat on the lathe processing needs . In order to ensure the mechanical seal stationary ring gland with a combination of good surface contact , it is best to fill up the cavity outer face flange portion for turning .
d) Install the mechanical seal , in a still sealed position using a good quality sealant to prevent leakage.
e) mechanical seal is in place, the pump and the motor must be in good and installed on the coupling after a fixed stationary ring and ring gland , and finally will be positioned to take the card to open . Otherwise , couplings and joints for adjusting the pendulum will cause partial radial and axial elevation will not only affect the mechanical seal static ring sealing surface contact , but also changes the mechanical seal tight static ring contact force, contact tightening force burned mechanical adjustable length seal over the General Assembly .
f) mechanical seal return pipe must be connected back to the pump inlet . Because the upper guide bearing a relief bore seal leakage , it serves to ensure the mechanical seal chamber pressure of not more than 490 kPa in effect, while the return pipe connected to a lower pressure , they may form a flow in order to promptly the movement of the mechanical seal sealing surface due to friction heat away .
Accory plastic security seal to protect the safety of goods and cargo protection, product storage, and other protective protection, plastic safety seal caulking materials and insulation, fully integrated, forming a solid positive angle insulation protection system, no rust, alkali resistance, aging, high strength anti-invasive, effective guarantee of a positive angle vertical flat, plastic seals on both sides of the network structure, so that the bonding closer and more solid.
Hi,
回复删除A mechanical seal or gasket that fills the gap between two and extra mating surfaces in order to prevent leakage from the jointed object or into the jointed object while they are joined under compression. For such activities you need gasket material sheet that are readily available in the market.